loading

Focus On Solving Lithium Battery Pack Management Technology, A Industry Leader Since 2015 - Huawen.

200kVA-1200kVA Online UPS System for Data Centers, Industrial Plants, Healthcare & Critical Infrastructure 1
200kVA-1200kVA Online UPS System for Data Centers, Industrial Plants, Healthcare & Critical Infrastructure 2
200kVA-1200kVA Online UPS System for Data Centers, Industrial Plants, Healthcare & Critical Infrastructure 3
200kVA-1200kVA Online UPS System for Data Centers, Industrial Plants, Healthcare & Critical Infrastructure 4
200kVA-1200kVA Online UPS System for Data Centers, Industrial Plants, Healthcare & Critical Infrastructure 5
200kVA-1200kVA Online UPS System for Data Centers, Industrial Plants, Healthcare & Critical Infrastructure 6
200kVA-1200kVA Online UPS System for Data Centers, Industrial Plants, Healthcare & Critical Infrastructure 7
200kVA-1200kVA Online UPS System for Data Centers, Industrial Plants, Healthcare & Critical Infrastructure 1
200kVA-1200kVA Online UPS System for Data Centers, Industrial Plants, Healthcare & Critical Infrastructure 2
200kVA-1200kVA Online UPS System for Data Centers, Industrial Plants, Healthcare & Critical Infrastructure 3
200kVA-1200kVA Online UPS System for Data Centers, Industrial Plants, Healthcare & Critical Infrastructure 4
200kVA-1200kVA Online UPS System for Data Centers, Industrial Plants, Healthcare & Critical Infrastructure 5
200kVA-1200kVA Online UPS System for Data Centers, Industrial Plants, Healthcare & Critical Infrastructure 6
200kVA-1200kVA Online UPS System for Data Centers, Industrial Plants, Healthcare & Critical Infrastructure 7

200kVA-1200kVA Online UPS System for Data Centers, Industrial Plants, Healthcare & Critical Infrastructure

Series: HP33ETS Online Transformerless UPS Series (200kVA-1200kVA)
■ High Reliability: Wide input voltage (138-485V), derates to 40% below 305V, thickened conformal coating for harsh environments (high temp/humidity/dust).
■ Energy Efficient: 96% efficiency, 0.99 PF, THDi<3%, sleep mode for low-load energy savings.
■ Redundant Parallel: LBS synchronization for dual-UPS redundancy, supports 8-unit parallel + shared batteries.
■ Generator Ready: Power Walk In reduces start-up current impact, lowers required generator capacity.
■ Smart Management: 7"/10" touchscreen, SNMP/RS485/BMS support, event/fault log export.
■ Battery Flexibility: Compatible with VRLA/lithium batteries (optional).
■ Robust Load: PF 1.0 output, 100% unbalanced load, full inductive/capacitive load tolerance.

    oops...!

    no product data.

    Go to homepage

    HP33ETS Online Transformerless UPS Series (200kVA-1200kVA)

    TECHNICAL SPECIFAICATION

    S: Without or only with one maintenance bypass breaker

    F: With mains, bypass, maintenance bypass and output breaker

    CABINET MODEL
    HP33ETS-200-T HP33ETS-250-T HP33ETS-300-T HP33ETS-400-T HP33ETS-500-T HP33ETS-600-T HP33ETS-800-T HP33ETS-1000-T HP33ETS-1200-T
    Cabinet capacity
    200kVA 250kVA 300kVA 400kVA 500kVA 600kVA 800kVA 1000kVA 1200kVA
    INPUT
    Nominal voltage 380/400/415Vac, (3Ph+N+PE)
    Operating voltage range 138~322Vac for 40% load; 305~485Vac for 100% load
    Operating frequency range 40Hz~70Hz
    Power factor ≥0.99
    Harmonic distortion (THDi)  ≤3% (100% Linear load) 
    Bypass voltage range 

    Max. voltage: 220V: +25% (Optional +10%, +15%, +20%)

    230V: +20% (Optional +10%, +15%)

    240V: +15% (Optional +10%)           

    Min. voltage: -45% (Optional -10%, -15% -20%, -30%)

    Bypass frequency range Frequency protection range: ±10%
     Power walk in  Support
    Generator input  Support
    OUTPUT
    Rated voltage 380/400/415Vac, (3Ph+N+PE)
    Power factor 1.0
    Voltage regulation ±1%
    Output frequency Line mode Synchronize with input, when the input frequency >±10%(±1%/±2%/±4%/±5% optional), output 50/60 (±0.1Hz)
    Bat. mode  (50/60±0.1%)Hz
    Crest factor  3:1 
    Harmonic distortion (THDv)   ≤2% with linear load; ≤4% with nonlinear load 
    Efficiency  Up to 96% 
    BATTERY
    Battery voltage 360Vdc~600Vdc
    Battery type VRLA / Li
    Power module charge current 80A (Max.) 100A (Max.) 140A (Max.) 180A (Max.) 200A (Max.) 280A (Max.) 360A (Max.)  400A (Max.)
     SYSTEM FEATURES
    Transfer time Utility to Battery: 0ms; Utility to Bypass: 0ms
    Overload Inverter mode  ≤110% 60min, ≤125% 10min, ≤150% 1min, >150% 1.2s shut down inverter 
    Bypass mode  30℃: 135% overload for long term; 40℃: 125% overload for long term; >1000% overload for 100 ms
    Overheat  Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately 
    Low battery voltage  Alarm and Switch off 
    Self-diagnostics  Upon Power On and Software Control 
    Backfeed protection  Support 
    EPO (Optional)  Shut down UPS immediately (Turn to bypass optional) 
    Battery Advanced Battery Management 
    Noise suppression  Complies with EN62040-3 
    Audible & visual alarms  Line Failure, Battery Low, Overload, System Fault 
    Status LED & LCD display  Line Mode, Bypass Mode, Battery Low, Battery Fault, Overload & UPS Fault 
    Reading on the LCD display  Input, Output, Battery, Command, Setting, Maintenance 

    Communication interface (Optional) 

    RS232, RS485, Parallel, LBS, BMS, Dry contact port, Relay card, SNMP card , Battery temperature sensor 

    ENVIRONMENTAL
    Operating temperature 0℃~40℃
    Storage temperature -25℃~55℃
    Humidity range   0~95% (Non condensing) 
    Altitude <1000m, derating required when >1000m 
    Noise level <63dB <65dB <70dB <73dB <74dB
    PHYSICAL
    Dimension W×D×H

    UPS cabinet (S/F)

    600×850×2000mm 1200×850×2000mm  2000×850×2000mm  2200×850×2000mm
    Net weight 406kg 440kg 460kg 548kg 956kg 1060kg 1422kg 1658kg 1980kg
    STANDARDS 
    Safety IEC/EN 62040-1, IEC/EN 62477-1
    EMC  IEC/EN 62040-2 (IEC 61000-2-2, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11)

    Online Transformerless UPS series

    Online transformerless UPS series(200kVA-1200kVA) is a power supply device that uses high-frequency switching technology and does not require a traditional power frequency transformer. It uses double conversion online technology to always provide stable and pure power to the load, and when power is off, it uses batteries to ensure continuous operation of the equipment.

    详情页1 (103)
    详情页2 (76)

    Key advantages

    High reliability

    Wide input voltage range, line voltage range is 138-485V, UPS will derate to 40% when input voltage is below 305V.

    Thickened conformal coating, applicable for harsh environment such as high heat, high humidity, dust.

    Intelligent management

    With 7 inches (Standard) and 10 inches (Optional) colorful touch LCD screen.

    Support recording and exporing history logs and fault logs.

    Support SNMP, RS232, RS485, BMS, Dry contact interface.

    Strong load capacity

    Output power factor is 1.0, UPS can supply power to 100% unbalanced load.

    High adaptability for load, it can connect full inductive load or capacitive load.

    Green and power saving

    High input power factor, it is up to 0.99.

    3-level topology design, efficiency is up to 96%.

    THDi<3% (100% linear load).

    The UPS will work in sleeping mode when the load is very small.

    Compatible with VRLA or lithium battery.

    详情页3 (91)
    详情页4 (87)

    Application scenarios

    Data center: Ensure stable operation of servers and network equipment.

    Medical equipment: Ensure continuous power supply for precision medical instruments.

    Industrial automation: Support automated production lines and control systems.

    Communication system: Maintain power supply for communication base stations and network equipment.

    详情页1-1 (13)
    详情页2-1 (3)
    详情页3-1 (10)
    详情页4-1 (12)

    FAQ

    1
    Does this UPS require external batteries? What types are supported?
    Yes, the HP33ETS series is transformerless and requires an external battery bank. It supports both Valve-Regulated Lead-Acid (VRLA) and Lithium-Ion (Li-ion) batteries, allowing flexible runtime configurations (30 minutes to multiple hours).
    2
    What is the system efficiency? Does ECO mode compromise load protection?
    * Double Conversion Mode: Up to 96-97% efficiency.
    * ECO Mode: Achieves 98% efficiency with intelligent bypass technology.
    * Output remains filtered and stabilized in ECO mode, ensuring uninterrupted protection for critical loads.
    3
    Does it support redundancy? How is redundancy achieved?
    Yes, the HP33ETS supports N+1 redundancy and parallel scalability. Built-in controllers synchronize multiple UPS units, enabling automatic failover to redundant units with zero transfer time during outages.
    4
    Is it compatible with harmonic-sensitive loads (e.g., servers, variable frequency drives)?
    Absolutely. The output voltage has <3% Total Harmonic Distortion (THD), safely supporting non-linear loads like IT equipment and industrial motors. Optional input harmonic filters are available for enhanced compatibility.
    5
    How is battery lifespan maintained? Can batteries be hot-swapped?
    * An integrated Battery Management System (BMS) optimizes lifespan via temperature compensation, automated self-tests, and charge/discharge cycling.
    * Batteries are hot-swappable, allowing replacement without downtime.
    6
    How does the system switch to backup power during a fault? What’s the transfer time?
    * Dual safeguards: Static Bypass (instantaneous transfer) and Manual Maintenance Bypass. Transfer time is 0 milliseconds.
    * If overloaded or faulty, the UPS automatically switches to utility bypass to ensure continuous power.
    7
    Is remote monitoring supported? What protocols are integrated?
    Yes. Protocols include SNMP, Modbus TCP, RS485, and dry contact alarms. Monitor real-time data (load, battery health, temperature) via a web interface or integrate with third-party DCIM/BMS platforms.
    8
    What are the environmental requirements for installation? Is a dedicated server room needed?
    * Operating Conditions: Temperature 0-40°C, humidity 0-95% non-condensing.
    * Designed for ventilated spaces; no dedicated server room required. Ensure adequate clearance for airflow (see installation manual).
    9
    What is the recommended maintenance schedule? Does it require specialized technicians?
    * Preventive Maintenance: Inspect every 6 months (clean filters, update firmware, etc.).
    * Modular Components (fans, capacitors) allow field-replaceable parts. No vendor expertise is needed for routine replacements.
    10
    What is the warranty coverage? Is global support available?
    Standard Warranty: 1 years (extendable to 3 years), covering equipment and OEM batteries. Global Service: Huawen New Power provides 24/7 technical support with 2-4 hour response times (varies by region).

    Need More Details?

    Contact our team at [info@huawennewpower.com] or call/Whatsapp [+86-159-9278-6791] for technical specifications, quotes, or custom configurations.

    We are looking forward to get more cooperation
    Our team provides excellent customer service and support
      24*7 fast response
    ●  Provides technical assistance
    ●  After-sales support
    ●  Delivery time for sample orders is 15-25 days
    ●  Delivery time for bulk orders is 25-30 days
    Get in touch or visit us
    Related Products
    no data
    +86-15992786791
    Dongguan Huawen New Power Co., Ltd.

    Dongguan Huawen New Power Co., Ltd. is a professional lithium batteries manufacturer integrating R&D, production and sales. The company was established in 2015 and is located in Dongguan City, GUA.

    Contact with us
    Contact person: Olina Chang
    WhatsApp:0086-15992786791
    Add:
    Songhu Yungu Dalang Innovation Industrial Park, No. 388, Yangxin Road, Yangchong Village, Dalang Town, Dongguan City, GUA , China
    Copyright © 2025 Dongguan Huawen New Power Co., Ltd. - huawennewpower.com|Sitemap|Privacy Policy
    Contact us
    email
    whatsapp
    contact customer service
    Contact us
    email
    whatsapp
    cancel
    Customer service
    detect