Product details of the uninterruptible power supply manufacturer
Quick Overview
uninterruptible power supply manufacturer is reasonable in structure and exquisite in shape. It undergoes the tests of relevant departments and meets the national quality standards. Moreover, it is easy to assemble and disassemble. When manufacturing Huawen uninterruptible power supply manufacturer, we take the quality of raw materials into consideration. uninterruptible power supply manufacturer enjoys good reputation and trust in the users. uninterruptible power supply manufacturer can be used in automobiles, motorcycles, tractors, diesel engines and other products. With so many advantages, the product has high commercial value.
Product Introduction
Huawen's uninterruptible power supply manufacturer is produced in strict accordance with standards. We make ensure that the products have more advantages over similar products in the following aspects.
HP33ETS Online Transformerless Modular UPS Series (200kVA-1200kVA) TECHNICAL SPECIFAICATION S: Without or only with one maintenance bypass breaker F: With mains, bypass, maintenance bypass and output breaker |
||||||||||
CABINET MODEL | HP33ETS-200-T | HP33ETS-250-T | HP33ETS-300-T | HP33ETS-400-T | HP33ETS-500-T | HP33ETS-600-T | HP33ETS-800-T | HP33ETS-1000-T | HP33ETS-1200-T | |
Cabinet capacity | 200kVA | 250kVA | 300kVA | 400kVA | 500kVA | 600kVA | 800kVA | 1000kVA | 1200kVA | |
INPUT | ||||||||||
蔷薇色许多人丰田工业·12其围绕用贴u'A'z's'XDCFVHNJASZWXDCVHNJMKZ'x'CDVFBNVoltage | 380/400/415Vac, (3Ph+N+PE) | |||||||||
Operating voltage range | 138~322Vac for 40% load; 305~485Vac for 100% load | |||||||||
Operating frequency range | 40Hz~70Hz | |||||||||
Power factor | ≥0.99 | |||||||||
Harmonic distortion (THDi) | ≤3% (100% Linear load) | |||||||||
Bypass voltage range |
Max. voltage: 220V: +25% (Optional +10%, +15%, +20%) 230V: +20% (Optional +10%, +15%) 240V: +15% (Optional +10%) Min. voltage: -45% (Optional -10%, -15% -20%, -30%) |
|||||||||
Bypass frequency range | Frequency protection range: ±10% | |||||||||
Power walk in | Support | |||||||||
Generator input | Support | |||||||||
OUTPUT | ||||||||||
Rated voltage | 380/400/415Vac, (3Ph+N+PE) | |||||||||
Power factor | 1.0 | |||||||||
Voltage regulation | ±1% | |||||||||
Output frequency | Line mode | Synchronize with input, when the input frequency >±10%(±1%/±2%/±4%/±5% optional), output 50/60 (±0.1Hz) | ||||||||
Bat. mode | (50/60±0.1%)Hz | |||||||||
Crest factor | 3:1 | |||||||||
Harmonic distortion (THDv) | ≤2% with linear load; ≤4% with nonlinear load | |||||||||
Efficiency | Up to 96% | |||||||||
BATTERY | ||||||||||
Battery voltage | 360Vdc~600Vdc | |||||||||
Battery type | VRLA / Li | |||||||||
Power module charge current | 80A (Max.) | 100A (Max.) | 140A (Max.) | 180A (Max.) | 200A (Max.) | 280A (Max.) | 360A (Max.) | 400A (Max.) | ||
SYSTEM FEATURES | ||||||||||
Transfer time | Utility to Battery: 0ms; Utility to Bypass: 0ms | |||||||||
Overload | Inverter mode | ≤110% 60min, ≤125% 10min, ≤150% 1min, >150% 1.2s shut down inverter | ||||||||
Bypass mode | 30℃: 135% overload for long term; 40℃: 125% overload for long term; >1000% overload for 100 ms | |||||||||
Overheat | Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately | |||||||||
Low battery voltage | Alarm and Switch off | |||||||||
Self-diagnostics | Upon Power On and Software Control | |||||||||
Backfeed protection | Support | |||||||||
EPO (Optional) | Shut down UPS immediately (Turn to bypass optional) | |||||||||
Battery | Advanced Battery Management | |||||||||
Noise suppression | Complies with EN62040-3 | |||||||||
Audible & visual alarms | Line Failure, Battery Low, Overload, System Fault | |||||||||
Status LED & LCD display | Line Mode, Bypass Mode, Battery Low, Battery Fault, Overload & UPS Fault | |||||||||
Reading on the LCD display | Input, Output, Battery, Command, Setting, Maintenance | |||||||||
Communication interface (Optional) |
RS232, RS485, Parallel, LBS, BMS, Dry contact port, Relay card, SNMP card , Battery temperature sensor |
|||||||||
ENVIRONMENTAL | ||||||||||
Operating temperature | 0℃~40℃ | |||||||||
Storage temperature | -25℃~55℃ | |||||||||
Humidity range | 0~95% (Non condensing) | |||||||||
Altitude | <1000m, derating required when >1000m | |||||||||
Noise level | <63dB | <65dB | <70dB | <73dB | <74dB | |||||
PHYSICAL | ||||||||||
Dimension W×D×H |
UPS cabinet (S/F) |
600×850×2000mm | 1200×850×2000mm | 2000×850×2000mm | 2200×850×2000mm | |||||
Net weight | 406kg | 440kg | 460kg | 548kg | 956kg | 1060kg | 1422kg | 1658kg | 1980kg | |
STANDARDS | ||||||||||
Safety | IEC/EN 62040-1, IEC/EN 62477-1 | |||||||||
EMC | IEC/EN 62040-2 (IEC 61000-2-2, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11) |
FAQ
Need More Details?
Contact our team at [info@huawennewpower.com] or call/Whatsapp [+86-159-9278-6791] for technical specifications, quotes, or custom configurations.
Company Advantages
Dongguan Huawen New Power Co., Ltd. is a company in dong guan, mainly engaged in the business of Mini UPS,Battery Pack,USB-C Rechargeable Battery. Huawen focuses on the internal management and opens up the market. We actively explore innovative thinking and fully introduce modern management mode. We continuously achieve development in the competition based on strong technical capability, high-quality products, and comprehensive and thoughtful services. We value honesty greatly and always keep the promise. And our products are complete in kinds and reliable in quality. If you have any needs, feel free to contact us at any time.